A low-cost industrial waste-based point-of-use filter for treating pesticide contaminated water 机翻标题: 暂无翻译,请尝试点击翻译按钮。

会议集名/来源
WEFTEC 2019 - 92nd Annual Water Environment Federation's Technical Exhibition and Conference
出版年
2019
页码
2124-2125
会议日期
2019-09-21 - 2019-09-25
作者
Abbas, Tauqeer 1;Wadhawan, Tanush 2;Khan, Asad 3;McEvoy, John 4;Khan, Eakalak 5 1 Department of Civil and Environmental Engineering, North Dakota State University, 58108-6050, United States 2 Dynamita, Canada 3 Department of Chemical Engineering, COMSATS University Islamabad, Lahore Campus, Pakistan 4 Department of Microbiological Sciences, North Dakota State University, 58108-6050, United States 5 Department of Civil and Environmental Engineering and Construction, University of Nevada, 89154-4015, United States eakalak.khan@unlv.edu
摘要
This study explored the ability of industrial waste media alone and in combination with sand to treat six chlorinated pesticides in a continuous flow filter system. Results show that sand filtration alone was ineffective in treating water contaminated with pesticides. Industrial waste media similar to iron shaving (150 g) in combination with sand completely removed all six pesticides during 300 hours of continuous filtration.
机翻摘要
暂无翻译结果,您可以尝试点击头部的翻译按钮。
关键词
Costs (major);Industrial wastes;Pesticides;Waste treatment;Water filtration;Water pollution;Water treatment