Investigation of holdup and axial dispersion of liquid phase in a catalytic exchange column using radiotracer technique 机翻标题: 暂无翻译,请尝试点击翻译按钮。

来源
Applied radiation and isotopes: including data, instrumentation and methods for use in agriculture, industry and medicine
年/卷/期
2017 / 121 /
页码
51-60
ISSN号
0969-8043
作者单位
Bhabha Atom Res Ctr, Div Heavy Water, Bombay 400085, Maharashtra, India;Bhabha Atom Res Ctr, Isotopes Prod & Applicat Div, Bombay 400085, Maharashtra, India;Bhabha Atom Res Ctr, Isotopes Prod & Applicat Div, Bombay 400085, Maharashtra, India;Bhabha Atom Res Ctr, Isotopes Prod & Applicat Div, Bombay 400085, Maharashtra, India;Bhabha Atom Res Ctr, Isotopes Prod & Applicat Div, Bombay 400085, Maharashtra, India;Bhabha Atom Res Ctr, Div Heavy Water, Bombay 400085, Maharashtra, India;Bhabha Atom Res Ctr, Div Heavy Water, Bombay 400085, Maharashtra, India;Indian Inst Technol, Dept Chem Engn, Bombay 400076, Maharashtra, India;Bhabha Atom Res Ctr, Div Heavy Water, Bombay 400085, Maharashtra, India;
作者
Kumar, Rajesh;Pant, H. J.;Goswami, Sunil;Sharma, V. K.;Dash, A.;Bhanja, K.;Mohan, Sadhana;Mahajani, S. M.;Mishra, S.;
摘要
Holdup and axial dispersion of liquid phase in a catalytic exchange column were investigated by measuring residence time distributions (RTD) using a radiotracer technique. RTD experiments were independently carried out with two different types of packings i.e. hydrophobic water-repellent supported platinum catalyst and a mixture (50% (v/v)) of hydrophobic catalyst and a hydrophillic wettable packing were used in the column. Mean residence times and hold-ups of the liquid phase were estimated at different operating conditions. Axial dispersion model (ADM) and axial dispersion with exchange model (ADEM) were used to simulate the measured RTD data. Both the models were found equally suitable to describe the measured data. The degree of axial mixing was estimated in terms of Peclet number (Pe) and Bodenstein number (Bo). Based on the obtained parameters of the ADM, correlations for total liquid hold-up (H-T) and axial mixing in terms of Bo were proposed for design and scale up of the full-scale catalytic exchange column.
机翻摘要
暂无翻译结果,您可以尝试点击头部的翻译按钮。
关键词/主题词
Catalytic exchange column;Trickle bed contactor;Residence time distribution;Hydrophobic;Hydrophilic;Radiotracer;Bromine-82;Mean residence time;Holdup;Axial dispersion model;Axial dispersion with exchange model;Peclet number;Bodenstein number;